02312NUS WD5MIRULC10H RRU5909 2100MHz,-48VDC,9.8G,2T2R,2*60W DBS5900
RRU5909 2100MHz Technical Specifications
The technical specifications of an RRU5909 2100MHz include RF specifications, engineering specifications, and CPRI port specifications.
RRU5909 2100MHz RF Specifications
The radio frequency (RF) specifications include the supported radio access technologies
(RATs), frequency bands, TX/RX modes, capacity, output power, carrier configurations, and receiver sensitivity.
In the following, U is short for UMTS, L is short for LTE FDD,and N (FDD) is short for NR FDD.
In the following, NR SUL indicates that NR FDD is supported only in the uplink. It is abbreviated as N (SUL).
TX/RX modes and capacity RRU5909 2100MHz
Frequency Band(MHz) | Protocol- defined Band | TX/RX Modea | Capacity | Supported Bandwidth(MHz) |
2100 | Band 1/n1 | 2T2R |
UMTS:6 carriers (without MIMO) and 4 carriers(with MIMO) LTE FDD:2 carriers NR SUL:1 carriers NR FDD:2 carriers |
LTE FDD:5/10/15/20 NR(SUR):15/20 NR FDD:5/10/15/20 |
Output Power and Carrier Configurations
Output power and carrier configurations of an RRU5909 2100MHz
Frequency Band (MHz) | Maximum Output Powera | Output Power Configuration |
2100 | 2x60W | Typical Power Configuration Reference for RRU (Excluding NB-IoT) |
Input power of an RRU5909 2100MHz
Power Input Type | Operating Voltage |
-48 VDC | -36V DC to -57V DC |
Dimensions and Weight
Dimensions and weight of anRRU5909 1800MHz
Item | Specifications |
Dimensions (H xW x D) | 400 mm x 300 mm x 100 mm (15.75 in. x 11.81 in.x 3.94 in.) (12 L) |
Weight | Weight 15 kg (33.08 1b, excluding mounting kits) |
Environmental Specifications
Environmental specifications of an RRU5909 2100MHz
Item | Specifications |
Operating temperature | Without solar radiation: -40℃ to +55C (-40°℉ to+131°F) With solar radiation of 1120 W/m2:-40℃to+50℃(-40F to +122F) |
Relative humidity | 5% RH to 100%RH |
Absolute humidity | 1 g/m3 to 30 g/m3 |
Atmospheric pressure | 70 kPa to 106 kPa |
RRU5909 2100MHz CPRI Port Specifications
The CPRI port specifications include the number of CPRI ports, port protocol, port rate, and maximum level of cascading and maximum distance with a BBU.
CPRI port protocol and rate of an RRU5909 2100MHz
Number of CPRI Ports Protocol Type Port Rate (Gbit/s)
2 CPRI 1.25/2.5/4.9/9.8
The following table lists the maximum level of cascading and maximum distance between an RRU and a BBU when the RRU works in a single mode. When the RRU works in multimode concurrency scenarios, the maximum level of cascading and maximum distance between the multimode RRU and a BBU are determined by the capabilities for the mode with the lowest capabilities.
RRU5909 (2100 MHz)
The mapping version information about the RRU5909 (2100 MHz) is as follows:
Earliest mapping software version of the base station:SRAN12.1
PnP software versions supported by the base station: SRAN10.1 and SRAN11.1
The following describes the specification differences when the RRU5909(2100 MHz) is used in different versions:
From SRAN15.1 onwards, the RRU5909 (2100 MHz) can be configured with NR FDD carriers only in the uplink by using the ULand DL decoupling feature, which means that the RRU5909 supports NR SUL.